Your Privacy
We use cookies and similar technologies to personalize content and ads, provide social media features, and analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you've provided to them or that they've collected from your use of their services. You can manage your preferences or withdraw your consent at any time.
Privacy Policy

Manage Consent Preferences

We use cookies and similar technologies to help provide and improve our services. You can choose which categories you consent to below. You can change your preferences at any time.

Strictly Necessary Cookies

Always Active

These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms.

Marketing & Advertising

Advertising Cookies

These cookies may be set through our site by our advertising partners. They may be used by those companies to build a profile of your interests and show you relevant adverts on other sites. They do not store directly personal information, but are based on uniquely identifying your browser and internet device.

Analytics

Analytics Cookies

These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site.

Personalization

Personalization Cookies

These cookies enable the website to provide enhanced functionality and personalization. They may be set by us or by third party providers whose services we have added to our pages.

Jar Test Guide for Coagulants and Flocculants

What is a Jar Test?

A jar test is a laboratory-scale simulation of full-scale coagulation-flocculation processes used to determine the optimal type and dosage of coagulants and flocculants for water and wastewater treatment. By testing multiple chemical combinations under controlled conditions, operators can identify the most cost-effective treatment program before implementing changes at full scale. Jar testing is essential for both initial system design and ongoing optimization. For the chemistry behind the two steps — what coagulation does versus what flocculation does — see Coagulation vs Flocculation in Water Treatment.

When to Run Jar Tests

  • New system design: Before installing treatment equipment, to select chemicals and determine required dosages.
  • Process optimization: When effluent quality is poor or chemical costs are too high.
  • Seasonal changes: Water quality changes with temperature, rainfall, and production patterns.
  • New chemical suppliers: To verify performance before switching suppliers.
  • Effluent limit changes: When discharge standards become more stringent.
  • Regular QA/QC: Monthly or quarterly to ensure ongoing optimal performance.

Equipment and Materials Needed

Item Specification Notes
Jar test apparatus 4–6 paddle stirrers, variable speed Phipps & Bird or equivalent
Beakers / jars 1000 mL or 2000 mL Clear glass or plastic
Sample water 1–2 liters per jar Must be representative; test within 24 hours
Coagulants PAC, PFS, alum, ferric chloride Prepare 1% or 10% solutions
Flocculants Anionic / cationic PAM Prepare 0.1% solution, fresh
pH adjustment chemicals NaOH (1M) and H₂SO₄ (1M) For pH optimization
pH meter Calibrated Measure before and after
Turbidity meter NTU scale Measure supernatant quality
Pipettes / syringes Various sizes Accurate chemical dosing
Stopwatch / timer — Track mixing and settling times

Jar Test Mixing Speed (RPM): Rapid Mix vs Slow Mix

Mixing speed is the variable most often copied blindly from one jar test report to the next. The two mixing phases do different jobs, so they need different speeds:

Rapid mix (coagulation): a short, intense mix that spreads the coagulant through the whole jar before it hydrolyses. The procedure below starts at 100–200 RPM (G-value ~200–300 s⁻¹).

Slow mix (flocculation): gentle stirring that lets destabilised particles collide and grow without tearing the floc apart. The procedure below uses 20–50 RPM (G-value ~20–50 s⁻¹).

Treat these as starting points, not a standard. The same RPM gives a different G-value on paddles and jars of different shapes, so check your jar tester’s manual or G-value chart, and always record the RPM and mixing time next to each result. If the floc looks fine but breaks up during the slow mix, lower the speed; if it stays as pin floc, try a slightly longer or faster flocculation stage before changing the dose. For a deeper look at tuning the two stages, see how to optimize flocculation mixing speed and rapid mix vs slow mix in flocculation. For RPM-to-G conversion and Gt alignment, see Velocity Gradient (G Value) in Jar Testing.

Three G Values: Jar, Scale-Up, and Plant — Don’t Mix Them Up

Three different G values appear on this site, and they describe three different things. None of them is wrong — but each one only applies to its own job. Using a jar number to size a plant mixer, or a plant design number to run a jar test, will mislead you in both directions.

Where the number lives Rapid mix Flocculation What it is for
Jar test (this page) 100–200 RPM, about G 200–300 s⁻¹, for 1–3 minutes 20–50 RPM, about G 20–50 s⁻¹, for 10–20 minutes A starting point for the first screening round — low enough to run on a bench tester, strong enough to disperse the coagulant.
Scale-up check Plant mixers at G 300–500 s⁻¹ Plant flocculation at G 20–50 s⁻¹ Checking whether the plant’s equipment can reproduce the conditions the jar test used. This is this site’s scale-up practice, not a design standard.
Plant design band G 700–1,000 s⁻¹, contact 1–2 min Tapered G 50–80 → 20–40 → 10–20 s⁻¹, 15–30 min total; flocculation Gt 20,000–200,000 A design reference for new-build or retrofit drinking-water plants (ASCE/AWWA 1990; Virginia design regulation 12VAC5-590-871) — not a jar-test operating value.

The rule that ties the three rows together: RPM is only comparable on the same jar tester. Across equipment and across scales, compare the velocity gradient G and the contact time — the Gt product — not the RPM. A plant running at G 700–1,000 s⁻¹ for 10–30 seconds and a jar running at G 200–300 s⁻¹ for 1–3 minutes can still be compared, because Gt puts intensity and time on the same footing. For the conversion and a worked matching example, see Velocity Gradient (G Value) in Jar Testing.

Sources: the plant design band is from drinking-water plant-design guidance (ASCE/AWWA 1990) and Virginia regulation 12VAC5-590-871. The jar starting points are this guide’s procedure values, and the scale-up row is this site’s scale-up practice — neither is presented as an external standard.

Step-by-Step Jar Test Procedure

Step 1: Sample Preparation

Collect a representative water sample. Ensure it is well-mixed and reflects actual process conditions. Measure initial water quality parameters: pH, temperature, turbidity, color, COD, alkalinity. Pour equal volumes (typically 1000 mL) of sample into each jar. Label each jar with the test condition (dosage, chemical type, etc.).

Step 2: pH Adjustment (if needed)

If testing pH effect, adjust each jar to a different pH using dilute acid or base. Stir gently and measure pH to confirm target value. Common pH range to test: 5.5, 6.0, 6.5, 7.0, 7.5, 8.0.

Step 3: Coagulant Addition (Rapid Mix)

Start rapid mixing at 100–200 RPM (G-value ~200–300 s⁻¹). Add coagulant (PAC, PFS, alum, etc.) to each jar at different dosages. Mix rapidly for 1–3 minutes to ensure uniform dispersion and charge neutralization. Typical dosage series for initial screening: 10, 20, 50, 100, 150, 200 mg/L.

Step 4: Flocculant Addition (Slow Mix)

Reduce mixing speed to 20–50 RPM (G-value ~20–50 s⁻¹) for flocculation. Add flocculant (PAM) if testing polymer aid. Typical dosage: 0.5–5 mg/L. Mix slowly for 10–20 minutes to allow floc formation and growth. Observe floc size, strength, and settling characteristics during this period. The screening series above (10–200 mg/L PAC; 0.5–5 mg/L PAM) is a starting grid for the first round only, not a recommended dose. The optimum for your water is the dose that wins in your own jar test, bracketed by a worse result on both sides — see “From Jar Result to Plant Dose” below.

Step 5: Settling

Stop mixing and start timer. Allow flocs to settle undisturbed for 10–30 minutes. Record time for 50% of jar to clear (interface settling rate). Observe final settled sludge volume and supernatant clarity.

Step 6: Measurement and Evaluation

Collect supernatant sample from 2–3 cm below the surface (avoid disturbing settled sludge). Measure key parameters: turbidity, pH, color, COD, total phosphorus, etc. Record sludge volume (SV30): settled sludge volume after 30 min, in mL/L. Compare results across all test conditions. If COD is the parameter that must come down, compare the full set of options in our COD removal methods guide before locking in a dose.

Experimental Design Strategies

Screening Test (First Round)

When testing a new water source, start with a wide range to identify the effective dosage range:

Jar 1 2 3 4 5 6
PAC (mg/L) 10 25 50 100 150 200

Use this to find the approximate optimal range, then narrow down in the next round.

Optimization Test (Second Round)

Based on screening results, test a narrower range with smaller increments:

Jar 1 2 3 4 5 6
PAC (mg/L) 40 50 60 70 80 100

Flocculant Optimization

Once optimal coagulant dosage is found, test PAM dosage:

Jar PAC (mg/L) Anionic PAM (mg/L)
1 (control) 50 0
2 50 0.5
3 50 1.0
4 50 2.0
5 50 3.0
6 50 5.0

pH Optimization

Test different pH values at constant coagulant dosage to find the optimal pH range.

Product Comparison Test

When comparing products from different suppliers, test all at the same dosage and conditions:

Jar Product Dosage
1 Product A (current) 50 mg/L
2 Product B (supplier 1) 50 mg/L
3 Product C (supplier 2) 50 mg/L
4 Product A 60 mg/L
5 Product B 60 mg/L
6 Product C 60 mg/L

How to Interpret Results

Key Performance Indicators

  • Supernatant turbidity: Primary indicator of treatment effectiveness.
  • Floc size: Larger flocs settle faster; very small flocs indicate under-dosing.
  • Settling rate: How quickly the water clears; faster = better.
  • Sludge volume (SV30): Lower volume = less sludge disposal cost.
  • Final pH: Must be within acceptable range for discharge or downstream processes.
  • Residual coagulant: Avoid over-dosing which can increase residual metal.

Common Patterns

Observation What It Means Action
Small, scattered flocs Under-dosing or wrong pH Increase dosage; adjust pH
Large flocs, cloudy water Restabilization (over-dose) Decrease coagulant dosage
Flocs break on mixing Weak flocs; need polymer Add PAM as flocculant aid
Good settling but turbid top Pin floc carryover Add PAM or increase dosage slightly
Very large, fluffy flocs PAM over-dose Reduce polymer dosage
Different results each jar Sample not homogeneous Mix sample thoroughly before pouring

Reading the Dose: How Different Waters Shift the Answer

The same jar test procedure gives a different “best dose” for every water. The screening range above is only a starting grid — use the character of the water to decide where inside (or outside) that grid to look, and which second variable to test next.

  • Low-turbidity, low-alkalinity water (e.g. upland surface water, some drinking-water sources). Floc forms slowly and the optimum is often narrow. Start at the low end of the screening series and change pH in small steps before raising the dose — raising the dose first often restabilises the colloids and makes the water cloudier, which looks like failure but is really over-dosing. If the water is cold, expect slower floc formation and allow a longer slow-mix stage before judging the result.
  • High-turbidity water (e.g. river water after rain, construction or mining runoff). The optimum is usually broader and higher. Screen with wider dose steps first, and watch sludge volume (SV30) as well as turbidity — the cheapest dose is not the one with the clearest supernatant if it doubles the sludge to be handled.
  • High-colour / high-organic water (e.g. peaty water, some food-processing effluents). Turbidity alone misleads: colour and COD drive the dose more than suspended solids do. Measure colour and COD on the supernatant, not just turbidity, and expect the optimum to sit higher than a turbidity-only reading would suggest. If colour barely moves while turbidity clears, the coagulant type matters more than the dose — compare PAC against an iron-based coagulant (for example PFS) at the same dose before pushing the dose up. See the ferric sulfate coagulant guide and the PFS guide for the trade-offs.
  • Industrial wastewater with variable load (e.g. paper mill, textile, food processing). A single jar test is a snapshot. Test at least two samples — a normal-load sample and a peak-load sample — and pick a dose that works for both, even if it is not the optimum for either. A dose that is optimal only at average load will fail on the days that matter. For paper-mill water specifically, see the COD removal guide.
  • Water with high hardness or alkalinity. pH drift after dosing is the usual surprise: the coagulant consumes alkalinity, the pH drops, and the “optimum” moves. Record pH before and after in every jar, and if the final pH lands outside the discharge or downstream limit, the pH-adjustment step is part of the answer, not an afterthought.

General rule for all five cases: change one variable at a time, keep a blank (no chemical) jar in every round, and do not accept an optimum that sits at the edge of the tested range — if the best jar is the highest (or lowest) dose tested, run a second round around it.

Common Mistakes to Avoid

  • Not mixing sample thoroughly: settled solids cause inconsistent results between jars.
  • Adding chemicals all at once: add coagulant while stirrers are already running for uniform mixing.
  • Wrong mixing speed: too fast breaks flocs; too slow prevents proper formation.
  • Not measuring initial water quality: changes in influent quality can invalidate comparisons.
  • Testing too narrow a range: always include a control and a wide range in the first round.
  • Single round testing: at least 2–3 rounds needed for true optimization.
  • Ignoring temperature: cold water reduces coagulation efficiency; may need higher dosage.
  • Not verifying with full-scale: jar tests predict but don’t guarantee full-scale performance.
  • Using old polymer solutions: PAM solutions degrade after 24–48 hours; always prepare fresh.

Common Misreads — and How to Re-Check Them

Most “failed” jar tests are misread, not wrong. Before changing chemical or supplier, run these checks:

  1. Pin floc read as under-dosing. Tiny flocs that never grow can mean the dose is too low — or the pH is wrong, or the mixing is too weak to bring particles together. Re-check: run the same dose at two different pH values and one longer slow-mix time. If the floc grows with pH or time, the dose was fine.
  2. Cloudy supernatant read as “needs more chemical”. If the flocs are large but the water above them stays cloudy, the usual cause is restabilization from over-dosing, not under-dosing. Re-check: repeat with the dose halved. If the water clears, the first dose was too high.
  3. Good settling, turbid top. Fine particles stay suspended after the main floc settles. Re-check: add a small PAM dose (start at the low end of the range in Step 4) rather than more coagulant, and sample the supernatant from the same depth every time.
  4. One round, one answer. A single round that “finds” an optimum is a hypothesis, not a result. Re-check: repeat the best two conditions on a fresh sample on a different day. If the optimum moves by more than one dose step, the water changed — widen the range and re-test instead of locking the dose.
  5. Sample older than a day, or taken after a process upset. Jar tests on stale or unrepresentative samples optimise the wrong water. Re-check: note the sampling time on every result sheet; if the sample sat for more than 24 hours, or the plant was not running normally when it was taken, re-sample before acting on the result.
  6. Flocs that look right in the jar but break in the plant. The jar cannot reproduce plant hydraulics. Re-check: compare G-values and retention times, not RPM (see Scale-Up below), and confirm with a short full-scale trial at the jar-test dose before changing the plant setpoint.

If the same sample gives a different optimum twice, suspect the sample or the procedure before suspecting the chemical. A quick diagnostic path for cloudy effluent after a jar test is in the cloudy effluent troubleshooting guide; for a systematic list of causes, see coagulation–flocculation troubleshooting.

When the Jar and the Plant Disagree

A jar test that works and a plant that does not is a common result, not a contradiction. The jar controls everything; the plant adds hydraulics, holding time, and water that keeps changing. Work through the three common disagreements in this order before changing the chemical.

  1. Good floc in the jar, broken floc in the plant. Check the shear path first: pumps, pipe runs, and centrifuge feed lines can tear apart flocs that looked perfect in the beaker. Only after the hydraulics check out should the chemical be changed. Detail: coagulation–flocculation troubleshooting.
  2. The jar’s best dose fails at the plant. Check whether the plant water still matches the jar sample: pH, alkalinity, and temperature at the time of sampling. Then check whether the plant rapid-mix G falls inside the 300–500 s⁻¹ scale-up band in the table above — a mixer running well outside that band will not reproduce jar conditions at any dose. Detail: how to optimize flocculation mixing speed and rapid mix vs slow mix in flocculation.
  3. The same dose gives a different result every time. Suspect sampling and setup before suspecting the chemical: check that each jar was filled from a well-mixed sample, and check that the G-curve used to read the jar tester’s RPM matches the actual jar geometry — round or square, and the paddle type. Detail: Velocity Gradient (G Value) in Jar Testing.

If all three checks pass and the plant still disagrees with the jar, the jar program itself needs revisiting — a different dose series, a different pH window, or a pilot run at plant scale — not a larger dose of the same chemical.

Scale-Up Considerations

Jar test results provide a starting point, but full-scale operation typically requires adjustments:
– Dosage adjustment: Use the jar-test optimum as the starting point for full-scale dosage, then adjust in small steps against plant results — there is no fixed percentage that transfers a jar optimum to the plant.
– Mixing intensity: Ensure full-scale mixers provide appropriate G-values (rapid mix: 300–500 s⁻¹, flocculation: 20–50 s⁻¹).
– Retention time: Verify full-scale tanks provide sufficient contact time.
– Sludge handling: Jar test sludge volume can help estimate full-scale sludge production.
– Pilot testing: For large systems, run a pilot before full-scale implementation.
– Regular re-testing: Water quality changes over time; re-test quarterly or after process changes.

From Jar Result to Plant Dose: A Short Checklist

Use this before changing a plant setpoint on the basis of a jar test:

  1. Confirm the optimum is bracketed. The best dose has a worse result on both sides of it in the same round. If not, run another round.
  2. Confirm it repeats. Same dose wins on a second, fresh sample.
  3. Convert by G-value and time, not RPM. Check that the plant’s rapid-mix and flocculation stages deliver comparable mixing intensity (G-value) and contact time to the jar test. If the plant cannot match them, treat the jar dose as a starting point and adjust in small steps at full scale.
  4. Check the side effects at the chosen dose. Final pH within limits? Sludge volume acceptable? Residual metal within limits? If any answer is no, the “optimum” is not usable yet — test pH adjustment or a different coagulant.
  5. Decide the trial, not the permanent setpoint. Run the plant at the jar-test dose for a defined trial period (days, not hours), log turbidity, pH, dose and sludge, then review. Keep the previous setpoint written down so the trial can be reversed.
  6. Decide when to re-test. Quarterly as routine; immediately after a change in source water, supplier, discharge limit, or a sustained drift in effluent quality.
  7. Know when a jar test is not enough. If the question is whether the whole process train works (not just the chemistry), that is a pilot-test question — see Jar Test vs Pilot Test.

Jar RPM vs Plant Mixer Speed

Jar test RPM does not translate 1:1 to a full-scale mixer. A plant flash mixer, a hydraulic flocculator and a 2-litre jar have completely different geometry, so the useful link between them is mixing intensity (G-value) and contact time, not shaft speed. Use the jar test to find which chemical and dose range works, then ask your equipment or chemical supplier to check that the plant mixers deliver comparable intensity and time.

Advanced Jar Testing Techniques

  • Zeta potential measurement: Quantifies particle charge to optimize coagulant dosage.
  • Streaming current detector: Real-time charge measurement for process control.
  • Filterability test: Filter supernatant to predict downstream filtration performance.
  • Floc strength test: Re-shear flocs and measure re-flocculation ability.
  • Sequential dosing: Test split addition of coagulant for better performance.
  • Dual coagulant testing: Test PAC + PFS blends for synergistic effects.

Frequently Asked Questions

What RPM should I use for a jar test?
Use your jar tester’s rapid-mix and flocculation settings as a starting point (this guide starts at 100–200 RPM for rapid mix and 20–50 RPM for slow mix), then adjust based on floc behaviour. Report RPM and time with every result instead of copying one number from the internet.

Is jar test mixing speed the same as plant mixer speed?
No. Equipment geometry differs, so compare mixing intensity (G-value) and contact time rather than RPM. See the scale-up and jar vs plant sections above.

How many jars or doses should I run?
Run enough jars to bracket the dose you expect to need, plus one blank with no chemical. If the best result sits at the edge of the range, run a second round around it. You can turn the result into a plant dose with the dosage calculator, and for organics-driven projects see the COD removal methods guide.

Conclusion

Jar testing is the foundation of effective coagulation-flocculation process design and optimization. A well-designed jar test program can significantly reduce chemical costs while improving effluent quality. The key is to follow a systematic approach: start with broad screening, narrow down to optimal ranges, test multiple parameters (dosage, pH, polymer), and verify results at full scale. Regular jar testing should be part of every water treatment plant’s quality assurance program.

Need help with jar testing or interpreting results? Contact our technical team for expert guidance on optimizing your coagulation program.